Home About us Pressure Displacement Universal devices Why it is good Contact

 

Measure amplifiers



Larger
WG06
Product description:
WG06 is a amplifier/conditioner used to work with LVDT AC/AC transducers. WG06 supplies transducer and converts it's output signal to one of standard signal (4-20mA, +/-10V, +/-5V, 0-10V, 0-5V). Supply is 24VDC or AC. Supply is separated from the rest. Casing wide 22,5mm is rail-mounted.

Technical parameters:
Power supply 21÷28 V/90 mA DC or AC
Output signals ▪ 4÷20 mA
▪ ±10 V
▪ 0÷10 V
Basic error0,1%
Temperature stability0,01%/ºC
Separationmeasuring part is separated from supply stage

                           Look at technical specification


Larger
WG07
Product description:
WG07 is a amplifier/conditioner used to work with special versions of AC/AC LVDT transducers which need less current supply. WG07 supplies transducer and converts its output signal to standard signal 4-20mA in two wire system. WG07 operates in standard current loop and can be supplied 10 do 36VDC. Casing is wide 22,5mm and used is rail-mounted.

Technical parameters:
Voltage Supply current loop
Output signal 4÷20 mA
Basic error0,25%
Temperature stability0,03%/ºC
Separationno

                           Look at technical specification
 

Displacement measurement
LVDT transducers(AC/AC)

Measure amplifiers
 WG06
 WG07

LVDT transducers (AC/DC and DC/DC)

LVDT meters

Copyright: Peltron 2005 | created by OrangeDot